PictureDetail

CRONOSflex

 

imc CRONOSflex: input modules

As part of the imc CRONOS family, the new imc CRONOSflex continues the tradition for supporting direct measurements of virtually any sensor available for mechanical, electromechanical, and mechatronic measurements. Multi-channel mixed signals, whether analog inputs, counters and incremental encoder inputs, or field bus based signals such as CAN-bus, GM LAN or LIN… you name it: imc CRONOSflex measures it.

Modular measurements
With up to 100kSps per channel, and now supporting up to 2 million samples per second throughput in each base unit, as well as having software configurable high precision signal conditioners and integrated sensor power supplies - the imc CRONOSflex can take on even the toughest data acquisition challenges, while performing at high precision under demanding environmental conditions.

The most striking feature of the imc CRONOSflex system is the imc Click Mechanism - you can add or remove signal-conditioned analog input channels from your imc CRONOSflex system in seconds by simply "clicking" a module on or off the stack. The module's rigid case and automatic recognition by the imc STUDIO software provide the ultimate in flexible modularity. Alternatively, the imc CRONOSflex Modules may be distributed, connected with the base unit or other satellite blocks via standard Ethernet cable.

As with all imc data acquisition system inputs, the imc CRONOSflex Modules integrate signal conditioning, analog filtering, high precision 24-bit digitizers, and digital signal processing. As such, a variety of modules are available from imc—from the general purpose universal 8-channel UNI2-8 module (CRFX/UNI2-8), to more measurement specific modules.

 

 

Summary of imc CRONOSflex input modules

  UNI2-8 UNI4 LV3-8 ISO2-8 ISOF-8 HISO-8 HV-4U HV-2U2I DCB2-8
DCBC2-8 B-8
BC-8 BR2-4 ICPU2-8 AUDIO2-4 AUDIO2-4-MIC QI-4
Channels 8 4 8 8 8 8 4 2+2  8  8 8  8  4 8 4 4 4
TEDS Ja Ja Ja Ja  Ja optional   Ja3 Ja   Ja    Ja Ja Ja Ja Ja
Speed per Channel                                  
Max Sampling Rate 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz
Max Bandwidth 48 kHz 48 kHz 48 kHz 11 kHz 48 kHz 11 kHz 14 kHz 14 kHz 5 kHz 5 kHz 48 kHz 48 kHz 14 kHz 48 kHz 48 kHz 48 kHz 48 kHz
Voltage Mode                                  
Isolated   Ja   Ja Ja Ja Ja Ja             Ja Ja Ja
Voltage up to 10 V Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
Voltage up to 50 V Ja Ja Ja Ja Ja Ja Ja Ja           Ja Ja Ja Ja
Voltage up to 60 V
(Isolation up to 800 V)
          Ja Ja Ja                  
Voltage up to 1000 V           Ja Ja Ja                  
Current                                  
20 mA Internal Shunt Ja Ja       Ja     Ja Ja Ja Ja          
20 mA
Shunt Plug
Ja Ja Ja Ja Ja       Ja   Ja   Ja        
Temperature                                  
Thermocouple (TC) Ja Ja   Ja Ja Ja                      
RTD (PT100) Ja Ja   Ja Ja Ja                      
Bridge Mode (DMS)                                  
Full Bridge Ja Ja             Ja Ja Ja Ja Ja        
Half Bridge Ja Ja             Ja Ja Ja Ja Ja        
Quarter Bridge Ja Ja             Ja Ja Ja Ja Ja        
DC Excitation Ja Ja             Ja Ja Ja Ja Ja        
AC Excitation (CF)                         Ja        
Audio and Vibration                                  
IEPE Mode Integrated (ICP-, DeltaTron-, PiezoTron)                           Ja Ja Ja Ja
ICP Plug optional optional optional optional         optional   optional   optional        
Charge                                  
Charge Mode Integrated                                 Ja
Miscellaneous                                  
Sensor Supply Ja Ja optional optional   optional     Ja Ja Ja Ja Ja     Ja  
Sensor Supply / Channel   Ja                              
Module Width  in mm 62 43 43 43 43 83 82 82 62 43 62 43 43 62 62 62 62

 

Key:  Default  Not available  Optional

 


 

CRFX/UNI2-8

UNI2-8

8-channel Universal Input Module

The imc CRONOSflex Multipurpose Module (CRFX/UNI2-8) is ideal for measurements requiring many different types of signal conditioning, or where the signal conditioning requirements are unknown or likely to change. The 8 differential, analog input channels enable not only the measurement of voltage, current and IEPE/ICP sensors, but also direct measurement of temperature (thermocouples and PT100 / RTD), resistive bridges and strain gauge (full-, half- and 120 or 350 Ohm quarter bridge directly supported).

For the powering of external sensors or resistive bridge measurements, a software selectable (2.5 V to 24 V) sensor supply is included.

Highlights:

Virtually all physical sensors are directly supported

Very high signal bandwidth of up to 48 kHz

Software selectable quarter bridge completion 120 and 350 Ohm

 

 

 


 

imc CRONOSflex Messmodul UNI-4

UNI-4

4-channel, universal module with isolation

The imc CRONOSflex universale module (CRFX/UNI-4) offers maximum flexibility and versatility. The 4 channels enable not only the measurement of voltage, current and the connection of IEPE (ICP)-sensors but also temperature (thermocouples, PT100 and PT1000), bridges and strain gauges (full-, half- and quarter bridge with internal completion: 120 , 350 and 1 k ).
Channel-wise independently configurable supply voltages between 0.25 V to 24 V are provided for the supply of external sensors respectively bridge measurement.
The channels are individually galvanically isolated for the voltage measurement, current and thermocouple measurement. Each channel is equipped with an own simultaneous A/D converter and adjustable filter (e.g., anti-aliasing filter).

Highlights:

Individual galvanically isolated measurement of voltage-, current- and thermocouple-mode

Channel-wise individually configurable sensor supply

PT100 and PT1000 support

High signal bandwidth of up to 48 kHz

 

 

 

imc CRONOSflex Messmodul LV3-8

LV3-8

8-channel Module for High Resolution measurements of voltage and current

The imc CRONOSflex high resolution voltage, current* and IEPE/ICP* Module (CRFX/LV3-8), enables per channel software adjustable sampling rates of up to 100 kSamples/s/channel. With a very high analog bandwidth of 48 kHz per channel, the module is suitable for the measurements through the entire electromechanical range, including sound and vibration signals. Due to its highly dynamic input voltage range between +/- 0.005 V full scale and up to +/- 60 V full scale, and over voltage protection extending up to 80 V, it ensures reliable measurements in virtually any application.

Highlights:

High signal bandwidth, with per channel software selectable filtering (e.g. anti-aliasing filter) up to 48 kHz

Synchronous A/D conversion on all channels in the system

Supports imc Plug & Measure Transducer Electronic Data Sheets (IEEE 1451.4)*

*(using an optional available DSUB-15 terminal connection for 4 channels)

 

 

 


 

imc CRONOSflex Messmodul ISO2-8

ISO2-8

8-channel isolated module

The imc CRONOSflex High-Precision Module (CRFX/ISO2-8) with 8 isolated channels is ideal for the measurement of:

Voltage and current

Temperature (thermocouples and PT100)

IEPE (ICP) sensors

Highlights:

Isolated channels enable measurements in environments where the ground reference voltage conditions are not well defined

High signal bandwidth 11 kHz

Per channel software adjustable filter (e.g., anti-aliasing filter) and synchronous A/D converter

Supports imc Plug & Measure Transducer Electronic Data Sheets (IEEE 1451.4)

 

 

 


 

imc CRONOSflex Messmodul ISO2-8

ISOF-8

8-channel, faster and isolated differential amplifier

The ISOF-8 is an isolated differential amplifier with 8 galvanically isolated channels for highly accurate measurement of:

Voltage and current

Temperature (Thermocouple and PT100)

ICP-Sensors (with optional ICP connector)

Highlights:

Isolated channels, galvanically isolated inputs

Adjustable input voltage range (from ±50mV to ±60V)

High signal bandwidth to 48 kHz

Each channel with its own adjustable filter (e.g., anti-aliasing filter) and simultaneous A/D converter

Supports imc Plug & Measure (Transducer Electronic Data Sheets (IEEE 1451))

Typical Applications: Ideally suited for measurements with unclear potential conditions such as in-vehicle or in the railway sector.

 

 

  


 

imc CRONOSflex Messmodul HISO-8

HISO-8

8-channel, HV Isolated Measurement Module

The imc CRONOSflex Module high isolation module (CRFX/HISO-8) enables measurement of low voltage signals riding on a high or indeterminate common mode level of up to 800 V, including:

Voltage (±50 mV to ±60 V)

Temperature (thermocouple and Pt100)

Current (20 mA)

Highlights:

Each channel galvanically isolated, channel-to-channel and channel-to-ground

high isolation rating 800V CAT I / 300V CAT III

Typical applications:

Temperature measurements on high voltage battery or fuel cell terminals, e.g., hybrid or electric vehicles

Measurement of low voltage current shunt signal with high common mode

 

 

 


 

imc CRONOSflex Messmodul HV-4U

HV-4U

Module for measurement of high voltages

The imc CRONOSflex High Voltage input module (CRFX/HV-4U) is ideally suited for isolated measurements of high voltage signals up to ±1000 V, as encountered in power quality monitoring and power efficiency analysis of electrical drive systems or hybrid vehicles.

Highlights:

Measurement of voltages of up to 600 VRMS (CAT III) / 1000 VRMS (CAT II)

14 kHz analog bandwidth (-3 dB)

Phase accuracy better than 1° for measurements of up to the 50th harmonic of 50/60 Hz line voltage

Input ranges from ±1000 V to 2.5 V, selectable per channel

 

 

 


 

imc CRONOSflex Messmodul HV-2U2I

HV-2U2I

Module for the measurement of high voltage and current

With the HV-2U2I four-channel amplifier, two channels can be used for measuring voltages up to 1000 V, and two channels are available to measure with current probes.

Highlights:

Measurement of voltages of up to 600 Veff (CAT III)/1000 Veff (CAT II)

14 kHz analog bandwidth (-3 dB)

Phase accuracy better than 1° for measurements of up to the 50th harmonic of 50/60 Hz line voltage

Input ranges from ±1000 V to 2.5 V, selectable per channel

Direct support for use of Rogowski coils

Typical Applications: Power measurements, measurements on electric motors, batteries, fuel cells, etc.

 

 

 


 

CRFX/DCB2-8
imc CRONOSflex Messmodul DCB2-8
CRFX/DCBC2-8
imc CRONOSflex Messmodul DCBC2-8

DCB2-8 & DCBC2-8

8-channel Bridge Measurement Module

The imc CRONOSflex Bridge Measurement Module (CRFX/DCB2-8 and CRFX/DCBC2-8) supports eight differential, analog inputs with integrated sensor supply for the measurement of resistive bridges or strain gauges, as well as voltage, current* and IEPE/ICP-sensors*.

A software selectable (2.5 V to 24 V) sensor supply is included, for the powering of external sensors or resistive bridge / strain gauge.

Highlights:

Signal bandwidth of up to 5 kHz

Software selectable quarter bridge completion 120 and 350 Ohm

Available in a compact version (CRFX/DCBC2-8) with high-density DSUB-26-HD connections.**

*(using an optional available DSUB-15 terminal connection for 2/4 channels)
**(High density DSUB connections are not compatible with standard imc DSUB plugs, and so do not support optional ICP or Current modes.)

 

 

 


 

CRFX/B-8
imc CRONOSflex Messmodul B-8

B-8 & BC-8

8-channel Fast Bridge Measurement Module

The imc CRONOSflex Fast Bridge Measurement Module (CRFX/B-8 and CRFX/BC-8) has eight differential, analog inputs capable of measurements of resistive bridges or strain gauges, voltage, current* and IEPE/ICP-sensors*.

A software selectable (2.5 V to 24 V) sensor supply is included, for the powering of external sensors or resistive bridge / strain gauge networks.

Highlights:

Very high signal bandwidth of up to 48 kHz per channel

Software selectable quarter bridge completion 120 and 350 Ohm

Available in a compact version (CRFX/BC-8) with high-density DSUB connections.**

*(using an optional DSUB-15 shunt plug for 2 channels)
**(High density DSUB connections are not compatible with standard imc DSUB plugs, and so do not support optional ICP or Current modes.)

 

 

 


 

CRFX/BR2-4
imc CRONOSflex Messmodul BR2-4

BR2-4

4-channel High Precision Bridge Measurement Module

The imc CRONOSflex Bridge Measurement Module (CRFX/BR2-4) enables measurements of four resistive bridges or strain gauges, supplied with a software selectable choice of either DC or CF (AC) excitation.

Highlights:

Carrier frequency excitation (5 kHz) for bridges and LVDT

Single and dual sense line configurations are supported (e.g., 5/6-wire connection with full bridge)

Symmetric bridge supply of 1 V, 2.5 V, 5 V and with DC and CF (AC) mode

Open cable recognition

Integrated calibration resistor for shunt calibration

Software selectable quarter bridge completion 120 and 350 Ohm

Supports imc Plug & Measure Transducer Electronic Data Sheets (IEEE 1451.4)

 

 

 


 

CRFX/ICPU2-8
imc CRONOSflex Messmodul ICPU2-8

ICPU2-8

8-channel IEPE/ICP-Measurement Module

The imc CRONOSflex IEPE/ICP Measurement Module (CRFX/ICPU2-8) is ideal for use in sound and vibration measurement engineering.

Highlights:

 Direct connection of IEPE/ICP-sensors via BNC inputs

High signal bandwidth of up to 48 kHz per channel

Wide input-voltage range of ±5 mV to ±50 V, individually software selectable per channel

Input coupling switchable via software: DC, AC, AC with current supply

Supports imc Plug & Measure Transducer Electronic Data Sheets (IEEE 1451.4 )

Typical applications:

Noise and vibration analysis

General measurement of dynamic acceleration

 

 

 


 

CRFX/AUDIO2-4
imc CRONOSflex Messmodul AUDIO2-4

AUDIO2-4 & AUDIO2-4-MIC

4-channel Audio Measurement Module

The imc CRONOSflex Audio Measurement Module (CRFX/AUDIO2-4) is specially designed for acquisition of sound and vibration data.
In addition, acquisition using ICP™ - or DeltaTron-Sensors®.
The module can be used for very precise measurements over a wide voltage range. It stands out by a very large signal to noise and high signal fidelity. In combination with the wide bandwidth and the 24 bit resolution, a broad scope of measurement applications are covered.
Next to each signal input at the front of the module there is a LED for a cable breakage recognition in measurement mode/coupling "AC with current feed"

Highlights:

Channel individual galvanic isolation

Signal bandwidth 48 kHz

large signal-to-noise ratio (-110dB SNR)

low signal distortion (-115dB THD)

Supports imc Plug & Measure (TEDS, Transducer Electronic Data Sheets (IEEE 1451)

Optional supply unit for a condenser microphone available (AUDIO2-4-MIC)

Typical applications: noise measurements, noise and vibration analysis, measuring accelerations

 

 

 

 


 

CRFX/QI-4
imc CRONOSflex Messmodul QI-4

QI-4

4-channel charge- and audio measurement module

The imc CRONOSflex charge amplifier module (CRFX/QI-4) is especially suited for quasi-static as well as dynamic charge measurements. By means of piezoelectric sensors, it is possible to measure forces, pressure and acceleration, as well as to perform analysis of solid-borne noise such as that occurring in engine indication on vehicle test stands.
As an alternative to standard BNC terminals, triaxial terminals are available which allow the use of charge sensors with built-in TEDS (Transducer Electronic Data Sheet).
The module is additionally designed for acoustical measurements and vibration analysis with current-fed IEPE sensors such as ICP™-, DeltaTron®-, and PiezoTron® sensors are supported. Further, the module can be used for high-precision measurement across a wide voltage range.
The module features a very high signal-to-noise ratio and high fidelity. In combination with its large bandwidth of around 50 kHz and its 24-bit resolution, a wide scope of applications can be covered. The separate galvanic isolation for each channel provides for robust, interference-free signal capture.
Next to each measurement input on the CRFX/QI-4 module’s front panel, there is an LED for the purpose of cable break monitoring in the measurement mode/coupling "AC with current fed".

Highlights:

Charge measurement with low drift over time, for quasi-static measurements

Per-channel galvanic isolation

Signal bandwidth 48 kHz

High Signal-to-Noise ratio (-110 dB SNR)

Low signal distortion (-115 dB THD)