PictureDetail

C-series

 

imc C-SERIES: Device Options

The imc C-SERIES is available in two housing options: CS and CL.

imc C-SERIE - Gehäusevariante CS  
CS: up to 8 analog measurement inputs depending on model   CL: up to 16 analog measurement inputs depending on model

In addition, all models come standard with:

  • 8 digital inputs
  • 8 digital outputs
  • 4 analog outputs
  • 4 counter inputs for capture of RPM, displacements, etc.
  • CAN-Bus interface with 2 nodes

Comprehensive, intelligent trigger functions; limit monitoring; minimum, maximum and mean value storage; as well as internal signal processors (Online FAMOS) for extensive real-time computing and control functions 

 

All-Purpose & Powerful: CS-7008 & CL-7016

The universality of the CS-7008 and CL-7016 is hard to beat. Whether measuring voltage, current, strain, thermocouples or current powered sensors (ICP), these instruments can measure pretty much everything.

CS-7008

 

CL-7016

  imc CL-7016
8 analog, universal measurement inputs;
For the measurement of bridges and strain gauges, current and voltage, thermocouples, PT100, acceleration (ICP);
100 kHz sampling rate / 48 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16-bit resolution (with internal 24-bit processing)
  16 analog, universal measurement inputs;
For the measurement of bridges and strain gauges, current and voltage, thermocouples, PT100, acceleration (ICP);
100 kHz sampling rate / 48 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16-bit resolution (with internal 24-bit processing)

 

Multi-channel & Affordable: CS-1016 & CL-1032

The CS-1016 and CL-1032 are affordable instruments for tasks related to voltage and current measurements with sampling rates up to 20 kHz per channel. The input channels are differential and equipped with individual signal conditioning including filters.

CS-1016

 

CL-1032

  imc CL-7016
16 analog, differential measurement inputs
for measuring voltage and current signals;
20 kHz sampling rate / 6.6 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution
  32 analog, differential measurement inputs
for measuring voltage and current signals;
20 kHz sampling rate / 6.6 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution

 

High-Resolution, Flexible Voltage Measurement : CS-1208 & CL-1224

The CS-1208 and CL-1224 devices are 8 or 24 channel high-resolution instruments for tasks related to voltage and current measurements with sampling rates up to 100 kHz per channel. These devices are especially well suited for demanding voltage measurements in the 50 V and low noise voltage range.

CS-1208

 

CL-1224

  imc CL-7016
8 analog, differential measurement inputs;
For measuring voltage and current signals;
100 kHz sampling rate / 48 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution(with 24 Bit internal processing)
  24 analog, differential measurement inputs;
For measuring voltage and current signals;
100 kHz sampling rate / 48 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution(with 24 Bit internal processing)

 

High-Resolution, Flexible Voltage Measurement w/Isolated Inputs: CS-4108 & CL-4124

The CS-4108 and CL-4124 devices are particularly suitable for measuring tasks in environments with uncertain potential conditions, such as on test stands or large machinery. The input channels are electrically isolated, differential and equipped with individual signal conditioning including filters.

CS-4108

 

CL-4124

  imc CL-7016
8 analog, differential measurement inputs;
For measuring voltage and current signals, thermocouples, PT100;
100 kHz sampling rate / 11 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution (with 24 Bit internal processing)
  24 analog, differential measurement inputs;
For measuring voltage and current signals, thermocouples, PT100;
100 kHz sampling rate / 11 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution (with 24 Bit internal processing)

 

Affordable, DC Measurements w/Strain Gauges: CS-5008 & CL-5016

The CS-5008 and CL-5016 devices are particularly suitable for quasi-static measurements with strain gauges. They can be configured via software for collection of quarter, half and full-bridge measurements. 

CS-5008

 

CL-5016

  imc CL-7016
8 analog, differential measurement inputs;
For measuring w/strain gauges & bridges, voltage and current signals;
100 kHz sampling rate / 5 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution(with 24 Bit internal processing)
  8 analog, differential measurement inputs;
For measuring w/strain gauges & bridges, voltage and current signals;
100 kHz sampling rate / 5 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution(with 24 Bit internal processing)

 

Top-Quality, Dynamic Strain Gauge DC/CF-Measurement: CS-6004 & CL-6012

For strain gauge applications, the CS-6004 and CL-6012 devices, with their wide dynamic ranges and high levels of flexibility, are absolute leaders in quality and performance. They can measure quarter, half and full bridges in DC or CF-operation.

CS-6004

 

CL-6012

  imc CL-7016
4 analog, differential measurement inputs;
For measuring strain gauges/bridges (DC/CF), voltage and current signals;
20 kHz sampling rate / 8,6 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution (with 24 Bit internal processing)
  12 analog, differential measurement inputs;
For measuring strain gauges/bridges (DC/CF), voltage and current signals;
20 kHz sampling rate / 8,6 kHz band width per channel;
Aggregate sampling rate 400 kHz;
16 Bit resolution (with 24 Bit internal processing)

 

Noise and Vibration Analysis: CS-8008

CS-8008 is an 8-channel universal measuring device with sampling rates up to 50 kHz and a bandwidth of 22.4 kHz per channel. Any desired ICP™ sensor such as DeltaTron® accelerometers and microphones can be supplied and be connected directly to the amplifier. Along with simple time-domain signals, the CS-8008 can also display linear frequency and 1/3-octave spectra.

CS-8008

   
CS-8008   8 analog, differential measurement inputs;
For direct connections with IEPE Sensors and voltage measuring;
50 kHz sampling rate / 22,4 kHz band width per channel;
Option without 1/3 octave spectra: 100 kHz sampling rate / 48,6 kHz band width;
Aggregate sampling rate 400 kHz;
16 Bit resolution (with 24 Bit internal processing)
     

 

Power Measurement: CL-2108

The CL-2108 is a compact measurement system, which is equipped with 4 inputs for current transformers and 4 inputs for direct connection of voltages up to ± 1000 V and has a protection class of 600 V CAT III. It can carry out single-, two and three-phase power measurements, offering a convincing combination of affordable price and high precision. An optional software package for network voltage analysis is also available.

CL-2108

   
CL-2108   4 inputs for current transformers;
4 inputs for direct measurement of voltage up to 1000 V;
100 kHz sampling rate / 14 kHz band width per channel
Aggregate sampling rate 400 kHz;
16 Bit resolution (with 24 Bit internal processing)